Australia - Updated: 24-SEP-2003
hp.com home products and services support and drivers solutions how to buy
» contact hp
hp.com home hp OpenVMS ECOs

IMPORTANT NOTICE

The online distribution of OpenVMS and related product patches is being migrated to the HP ITRC (Information Technology Resource Center) patch distribution site. The new ITRC patch server will allow OpenVMS customers to take advantage of many enhanced features for patch searching and distribution.

Beginning August 1, 2003, OpenVMS and related Layered Product, publicly available patches will be available from the HP ITRC web site at

http://itrc.hp.com/service/patch/mainPage.do

The same patches will still be available from the existing patch server in Colorado Springs (http://www.support.compaq.com/patches/) through the end of October 2003, to give customers sufficient time to update their bookmarks and make the transition to the HP ITRC web site.

ECO kits will also be available by raw FTP from (ftp://ftp.itrc.hp.com/).

PLEASE UPDATE YOUR BOOKMARKS AND REGISTER ON THE NEW SITE NOW

Note: if you're having trouble connecting to the ITRC site, please delete any cookies for "itrc.hp.com" from your browser and try again. Report any difficulties with or suggestions to MrVMS

» Sydney CSC home page

Navigation
» ECOinfo main index
» Search ECOs
» Search FTP site
» Browse FTP site

ECO Indexes
» Chronological Index
» Indexed by Version
» Indexed by Rating
» Alpha Indexed by Name
» VAX Indexed by Name
» On Hold List

Associated Links
» OpenVMS Home Page
» OpenVMS News
» DIA/WIS Web Service

Feedback
» mail to CSC
.
Sydney Customer Support Centre OpenVMS ECO information
    Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)

VMS731_SHADOWING-V0100 Alpha V7.3-1 ECO Summary

To obtain this kit please call the Customer Support Centre or use the FTP site

Search for this ECO kit and dependencies
Search the Compaq FTP web site this kit (exact match)
Search the Compaq FTP web site this or related ECOs

    
      
    *OpenVMS] VMS731_SHADOWING-V0100 Alpha V7.3-1 ECO Summary
    
    New Kit Date:       18-SEP-2003
    Modification Date:  None
    Modification Type:  NEW KIT
    
    
    Copyright (c) Hewlett-Packard Company 2003.  All rights reserved.
    
    OP/SYS:     OpenVMS Alpha
    
    COMPONENT:  SHADOWING
    
    SOURCE:     Hewlett-Packard Company
    
    ECO INFORMATION:
    
         ECO Kit Name:  VMS731_SHADOWING-V0100
                        DEC-AXPVMS-VMS731_SHADOWING-V0100--4.PCSI
         ECO Kits Superseded by This ECO Kit:  None
         ECO Kit Approximate Size:  2064 Blocks
         Kit Applies To: OpenVMS Alpha V7.3-1
         System/Cluster Reboot Necessary:  Yes
         Rolling Re-boot Supported:  Yes
         Installation Rating: INSTALL_2
    
         To be installed by all customers using the following feature(s):
    
          -  SHADOWING
    
         This installation rating, based upon current  CLD  information,  is
         provided  to  serve as a guide to which customers should apply this
         remedial kit.   (Reference  attached  Disclaimer  of  Warranty  and
         Limitation of Liability Statement)
    
         Kit Dependencies:
    
         The following remedial kit(s) must be installed BEFORE
         installation of this kit:
    
           o  VMS731_PCSI-V0100
    
           o  VMS731_UPDATE-V0100
    
      
         In order to receive all the corrections listed in this
         kit, the following remedial kits should also be installed:
    
           o  None
    
    
    FILES PATCHED OR REPLACED:
    
    
          o  [SYSEXE]SHADOW_SERVER.EXE (new image)
    
             image name: "SHADOW_SERVER"
             image file identification:  "X-13"
             image file build identification:  "X9TD-0060030010"
             link date/time: 30-JUL-2003 06:04:46.49
             linker identification:  "A11-50"
    
    
          o  [SYS$LDR]SYS$SHDRIVER.EXE (new image)
    
             image name: "SYS$SHDRIVER"
             image file identification:  "X-3"
             image file build identification:  "X9TD-0060030010"
             link date/time: 30-JUL-2003 06:05:19.20
             linker identification:  "A11-50"
    
    
    
    
    PROBLEMS ADDRESSED IN THIS KIT
    
    New problems addressed in the VMS731_SHADOWING-V0100 kit
    
         o  Shadowset Aborts after node is shutdown
    
            Shadowsets on the remaining node of a multi-site cluster
            abort after the serving node of one member is shutdown.
    
            Images Affected: [SYS$LDR]SYS$SHDRIVER.EXE
    
    
    
    
         o  Host Based Volume Shadowing (HBVS) Mini Copy Problem
    
            When using HBVS, if Mini Copy is used to return a former
            Shadow Set Member (SSM) to a virtual unit, and that SSM
            is removed from the shadow set before the copy can
            complete, the user must execute the following commands
            before adding that SSM is added back into the shadow set:
    
                     $ SHOW DEVICE/BITMAP/FULL DSAnnnn:
                     $ DELETE /BITMAP x
    
           "DSAnnnn:" is the virtual unit and "x" is the BitMap ID
            displayed by the SHOW DEVICE/BITMAP/FULL command.  If
            multiple BitMap IDs are displayed, delete the one that
            has the SSM in the Bitmap Name portion of the display.
            If these steps are not taken, data integrity could be
            affected.
    
            Images Affected: [SYS$LDR]SYS$SHDRIVER.EXE
    
    
    
         o  Repair read bias calculation for multipath devices
    
            The read performance for a multiple member shadow set,
            that has multipath enabled members, has been using only
            the primary UCB, not the current UCB.
    
            Images Affected: [SYS$LDR]SYS$SHDRIVER.EXE
    
    
         o  Default read cost for locally remote device set to high
    
            Default read cost for locally remote device is set to
            high.
    
           Images Affected: [SYS$LDR]SYS$SHDRIVER.EXE
    
    
    
         o  INVEXCPTN Crash during shadow copy
    
            When doing a Controller Assisted Copy, available with HSC
            and HSJ controllers, if the source member gets an error
            an incorrect index is set up that results in a crash.
    
                   Crashdump Summary Information:
                   ------------------------------
                   Bugcheck Type:     INVEXCEPTN, Exception while
                                      above ASTDEL
                   Current Process:   NULL
                   Current Image:     <not available>
                   Failing PC:        FFFFFFFF 80268D60
                   Failing PS:        30000000 00000804
                   Module:            SYS$SHDRIVER
                   Offset:            0004AD60
    
                    :
                   Exception Frame:
                   R2  = FFFFFFFF 837A6380   R3  = 00000000 00000000
                   R4  = FFFFFFFF 839CB3C0   R5  = FFFFFFFF 83689D80
                   R6  = FFFFFFFF 839CB680   R7  = 00000000 00000000
                   PC  = FFFFFFFF 80268D60   PS  = 30000000 00000804
    
             Images Affected: [SYS$LDR]SYS$SHDRIVER.EXE
    
    
    
    
    INSTALLATION INSTRUCTIONS:
    
    
    INSTALLATION NOTES:
    
         Reboot Required.  HP strongly recommends that a reboot is performed
         immediately after kit installation to avoid system instability.
    
         If you have other nodes in your OpenVMS cluster, they must also  be
         rebooted  in  order  to make use of the new image(s).  If it is not
         possible or convenient to reboot the entire cluster at this time, a
         rolling re-boot may be performed.
    
    Installation Command
    
         Install this kit with the POLYCENTER Software installation utility
         by logging into the SYSTEM account, and typing the following at the
         DCL prompt:
    
         PRODUCT INSTALL VMS731_SHADOWING /SOURCE=[location of Kit]
    
         The kit location may be a tape drive, CD, or a disk directory that
         contains the kit.
    
         Additional help on installing PCSI kits can be found by typing
         HELP PRODUCT INSTALL at the system prompt
    
    
    Scripting of Answers to Installation Questions
    
         During installation, this kit will ask and require user response to
         several questions.  If you wish to automate the installation of
         this kit and avoid having to provide responses to these questions,
         you must create a DCL command procedure that includes the following
         definitions and commands:
    
          -  $ DEFINE/SYS NO_ASK$BACKUP TRUE
    
          -  $ DEFINE/SYS NO_ASK$REBOOT TRUE
    
          -  Add the following qualifiers to the PRODUCT INSTALL command and
             add that command to the DCL procedure.
    
               /PROD=DEC/BASE=AXPVMS/VER=V1.0
    
    
          -  De-assign the logicals assigned
    
         For example, a sample command file to install the VMS731_SHADOWING
         kit would be:
    
         $
         $ DEFINE/SYS NO_ASK$BACKUP TRUE
         $ DEFINE/SYS NO_ASK$REBOOT TRUE
         $!
         $ PROD INSTALL VMS731_SHADOWING/PROD=DEC/BASE=AXPVMS/VER=V1.0
         $!
         $ DEASSIGN/SYS NO_ASK$BACKUP
         $ DEASSIGN/SYS NO_ASK$REBOOT
         $!
         $ exit
    
    
    
    COPYRIGHT AND DISCLAIMER:
    
         (C) Copyright 2003 Hewlett-Packard Development Company, L.P.
    
         Confidential computer software.  Valid license from HP  and/or  its
         subsidiaries required for possession, use, or copying.
    
         Consistent  with  FAR  12.211  and  12.212,   Commercial   Computer
         Software,  Computer  Software Documentation, and Technical Data for
         Commercial  Items  are  licensed  to  the  U.S.   Government  under
         vendor's standard commercial license.
    
         Neither HP  nor  any  of  its  subsidiaries  shall  be  liable  for
         technical  or  editorial errors or omissions contained herein.  The
         information in this document is provided "as is"  without  warranty
         of  any  kind  and  is  subject  to  change  without  notice.   The
         warranties for HP products are set forth  in  the  express  limited
         warranty  statements  accompanying  such  products.  Nothing herein
         should be construed as constituting an additional warranty.
    
         DISCLAIMER OF WARRANTY AND LIMITATION OF LIABILITY
    
         THIS PATCH IS PROVIDED AS IS, WITHOUT WARRANTY OF  ANY  KIND.   ALL
         EXPRESS  OR  IMPLIED  CONDITIONS,  REPRESENTATIONS  AND WARRANTIES,
         INCLUDING ANY IMPLIED  WARRANTY  OF  MERCHANTABILITY,  FITNESS  FOR
         PARTICULAR PURPOSE, OR NON-INFRINGEMENT, ARE HEREBY EXCLUDED TO THE
         EXTENT PERMITTED BY APPLICABLE LAW.  IN NO  EVENT  WILL  COMPAQ  BE
         LIABLE  FOR  ANY  LOST REVENUE OR PROFIT, OR FOR SPECIAL, INDIRECT,
         CONSEQUENTIAL, INCIDENTAL OR PUNITIVE DAMAGES, HOWEVER  CAUSED  AND
         REGARDLESS  OF  THE  THEORY OF LIABILITY, WITH RESPECT TO ANY PATCH
         MADE AVAILABLE HERE OR TO THE USE OF SUCH PATCH.
    
    
privacy statement using this site means you accept its terms feedback to the webmaster