Australia - Updated: 24-SEP-2003
hp.com home products and services support and drivers solutions how to buy
» contact hp
hp.com home hp OpenVMS ECOs

IMPORTANT NOTICE

The online distribution of OpenVMS and related product patches is being migrated to the HP ITRC (Information Technology Resource Center) patch distribution site. The new ITRC patch server will allow OpenVMS customers to take advantage of many enhanced features for patch searching and distribution.

Beginning August 1, 2003, OpenVMS and related Layered Product, publicly available patches will be available from the HP ITRC web site at

http://itrc.hp.com/service/patch/mainPage.do

The same patches will still be available from the existing patch server in Colorado Springs (http://www.support.compaq.com/patches/) through the end of October 2003, to give customers sufficient time to update their bookmarks and make the transition to the HP ITRC web site.

ECO kits will also be available by raw FTP from (ftp://ftp.itrc.hp.com/).

PLEASE UPDATE YOUR BOOKMARKS AND REGISTER ON THE NEW SITE NOW

Note: if you're having trouble connecting to the ITRC site, please delete any cookies for "itrc.hp.com" from your browser and try again. Report any difficulties with or suggestions to MrVMS

» Sydney CSC home page

Navigation
» ECOinfo main index
» Search ECOs
» Search FTP site
» Browse FTP site

ECO Indexes
» Chronological Index
» Indexed by Version
» Indexed by Rating
» Alpha Indexed by Name
» VAX Indexed by Name
» On Hold List

Associated Links
» OpenVMS Home Page
» OpenVMS News
» DIA/WIS Web Service

Feedback
» mail to CSC
.
Sydney Customer Support Centre OpenVMS ECO information
    Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)

VMS73_DCL-V0300 Alpha V7.3 DCL ECO Summary

To obtain this kit please call the Customer Support Centre or use the FTP site

Search for this ECO kit and dependencies
Search the Compaq FTP web site this kit (exact match)
Search the Compaq FTP web site this or related ECOs

    
    
    *OpenVMS] VMS73_DCL-V0300 Alpha V7.3 DCL ECO Summary
    
    New Kit Date:       10-MAR-2003
    Modification Date:  Not Applicable
    Modification Type:  NEW KIT
    
    Copyright (c) Compaq Computer Corporation 2003.  All rights reserved.
    
    OP/SYS:     OpenVMS Alpha
    
    COMPONENT:  DCL
    
    SOURCE:     Compaq Computer Corporation
    
    ECO INFORMATION:
    
         ECO Kit Name:  VMS73_DCL-V0300
                        DEC-AXPVMS-VMS73_DCL-V0300--4.PCSI
         ECO Kits Superseded by This ECO Kit:  VMS73_DCL-V0200
         ECO Kit Approximate Size:  832 Blocks
         Kit Applies To:  OpenVMS Alpha V7.3
         System/Cluster Reboot Necessary:  Yes
         Rolling Re-boot Supported:  Yes
         Installation Rating:  INSTALL_3
                               3 - To  be  installed  by  customers  experiencing  the  problems
    		               corrected.
    
         Kit Dependencies:
    
           The following remedial kit(s), or later, must be installed BEFORE
           installation of this, or any required kit:
    
             VMS73_UPDATE-V0100
    
           In order to receive all the corrections listed in this
           kit, the following remedial kits, or later, should also be installed:
    
             None
    
    ECO KIT SUMMARY:
    
    An ECO kit exists for DCL on OpenVMS Alpha V7.3.
    This kit addresses the following problems:
    
    PROBLEMS ADDRESSED IN VMS73_DCL-V0300 KIT
    
         o  When unprocessed record lines are encountered in an input
            command file, DCL overwrites image failure status with the
            warning DCL-W-SKPDAT.  The overwrite of the status should only
            happen when images exited with a successful status.
    
              Images Affected:[SYSEXE]DCL.EXE
    
    
    
         o  A file created by DCL will erroneously inherit the file
            extension quantity value from a previously opened file.  For
            example:
    
              $ DIR/FULL LOGIN.COM
                        .
                        .
    
                        .
              File attributes:    Allocation: 18, Extend: 5000
    
              ** Note that LOGIN.COM has DEQ  set to 5000
    
              $ OPEN/READ/SHARE FILE LOGIN.COM
              $ CLOSE FILE
              $
              $ @tt/out=out.txt
              _$ put something in file
              %DCL-W-IVVERB, unrecognized command verb -
              check validity and spelling \PUT\
              _$  Exit
              $
              $ DIR/FULL OUT.TXT
    
              Directory $2$DKB0:[TEST]
    
              OUT.TXT;1                     File ID:  (8282,1,0)
              Size:            1/5004       Owner:    [SYSTEM]
              Created:    21-AUG-2002 10:35:50.40
              Revised:    21-AUG-2002 10:35:57.94 (1)
              File attributes:    Allocation: 5004, Extend: 5000,
                                  Global buffer count: 0
              Client attributes:  None
              Total of 1 file, 1/5004 blocks.
    
    
              Images Affected:[SYSEXE]DCL.EXE
    
    
    
    
         o  If an upcall enabled image's execution is interrupted with ^y,
            and execution of a DCL command procedure is entered as the
            first command at the ^Y DCL prompt, an access violation
            occurs.  For example:
    
              ^y
              $ @TEST
              %SYSTEM-F-ACCVIO, access violation, reason mask=00, virtual
              address=0000000000000004, PC=FFFFFFFF80B4FBEC, PS=0000001B
              ...
    
    
              Images Affected:[SYSEXE]DCL.EXE
    
    
    
         o  When running the XQP exercisor test, the test procedure
            displays the input prompt instead of executing a command
            passed on the command line invoking the image.  For example:
    
               $ xqpxr do 'p1' [xqpxr] xqpxr_test.dat -
                 /numf=1-
                 /sizf=500-
                 /rndf-
                 /exte=14-
                 /rnde-
                 /plac=vbn-
                 /dirc=1-
                 /dura=00:03:00.0-
                 /adda-
                 /acec=4-
                 /rnda-
                 /oper=(build,randio)-
                 /iotc=1
                XQPXR>
    
    
              Images Affected:[SYSEXE]DCL.EXE
    
    
    
         o  The following call to F$GETSYI, on a system that does not
            support partitioning, will crash the process:
    
              $ write sys$output f$getsyi("cpu_failover")
    
               Improperly handled condition, bad stack or no handler
               specified.
               Signal arguments:   Number = 0000000000000005
                                   Name   = 000000000000000C
                                            0000000000000004
                                            000000007FFAE000
                                            000000007FFAE000
                                            0000000000000012
                                      .
                                      .
                                      .
                                      .
              %DCL-S-RETURNED, control returned to process GUY
              %SYSTEM-F-ACCVIO, access violation, reason mask=00,
              virtual address=000000000000000C, PC=000000000000000C,
              PS=7FFAC4C3
    
              Images Affected:[SYSEXE]DCL.EXE
    
    
    
    
    PROBLEMS ADDRESSED IN VMS73_DCL-V0200 KIT:
    
      o  When the DCL PIPE command is issued in batch  mode,  it  skips
         over the DCL statement immediately following the PIPE command.
         This occurs when the ";" separator is followed  by  a  command
         sequence containing an "@filespec" command.
    
           Images Affected:  [SYSEXE]DCL.EXE
    
    
      o  Running the pipe command in a loop may result in  one  of  the
         following problems:
    
               o  DOUBLDEALO user mode bugchecks
    
               o  ACCVIO in various symbol manipulation routines
    
               o  SYMOVF error message
    
           Images Affected:  [SYSEXE]DCL.EXE
    
    
      o  A process that has spawned several jobs, using  a  combination
         of  SPAWN/WAIT  and  SPAWN/NOWAIT commands, stays in state HIB
         after all the spawned subprocesses have completed.
    
           Images Affected:  [SYSEXE]DCL.EXE
    
    
    PROBLEMS ADDRESSED IN VMS73_DCL-V0100 KIT:
    
      o  When an image run by a DCL  procedure  includes  a  line  that
         generates  a  skipped data warning immediately after the image
         line, the status from the image run is returned in R0 and  the
         warning is not caught by DCL.
    
           Images Affected:  [SYSEXE]DCL.EXE
    
    
      o  Attempting to execute the TCPIP$CONFIG.COM  procedure  results
         in an ACCVIO abnormally terminating the process.
    
           Images Affected:  [SYSEXE]DCL.EXE
    
    
      o  The PIPE command may cause a SYSTEM-F-MBTOOSML error  message.
         This  is  caused  by  the  command  overflowonig  the  mailbox
         handling the  data  between  the  subprocesses.   Raising  the
         SYSGEN parameter DEFMBXMXMSG has no effect.
    
           Images Affected:  [SYSEXE]DCL.EXE
    
    
      o  Support for the /PASSIVE qualifier has been added.
    
           /PASSIVE
    
           /PASSIVE=option
    
        Controls whether the FTP client or server initiates the
        data connection.  If this qualifier is not specified,
        the Internet Protocol appropriate value is used (OFF for
        IPv4, ON for IPv6).
    
        The underlying TCP/IP Networking product must recognize
        this qualifier and must support FTP passive in order for
        this qualifier to have an effect.
    
          Options:
    
           OFF      The FTP server initiates the data connection.
    
           ON       The FTP client initiates the data connection.
    
                    This is often used where a firewall between
                    the FTP client and server prevents the server
                    from making an outbound connection.
    
                    ON is the default value if only /PASSIVE is
                    specified.
    
           Images Affected:  [CLD]COPY.CLD
                             [CLD]DIRECTORY.CLD
    
    
    RELATED ARTICLES:
    
    Detailed articles describing the problems listed above may exist in
    the OPENVMS database(s).  To view these articles, open the appropriate
    product database and perform a query using either of the following
    search strings: 'VMS73_DCL-V0300' or 'VMS73_DCL'.
    
    ECO KIT ORDERING INSTRUCTIONS:
    
    If after an evaluation you wish to obtain this kit, request it
    electronically using the appropriate Advanced Electronic Services
    (AES) Service Tool.  If you are not familiar with how to request
    kits electronically, open the DIA, WIS or DSNLINK database and
    review the article entitled:
    
         [AES] How To Electronically Request ECO Kits Using Service Tools
    
    INSTALLATION NOTES:
    
    This kit requires a system reboot.  Compaq strongly recommends that
    a reboot is performed immediately after kit installation to avoid
    system instability
    
    If you have other nodes in your OpenVMS cluster, they must also be
    rebooted in order to make use of the new image(s).  If it is not
    possible or convenient to reboot the entire cluster at this time, a
    rolling re-boot may be performed.
    
    INSTALLATION INSTRUCTIONS:
    
    Install this kit with the POLYCENTER Software installation utility
    by logging into the SYSTEM account, and typing the following at the
    DCL prompt:
    
    PRODUCT INSTALL VMS73_DCL /SOURCE=[location of Kit]
    
    The kit location may be a tape drive, CD, or a disk directory that
    contains the kit.
    
    Additional help on installing PCSI kits can be found by typing
    HELP PRODUCT INSTALL at the system prompt
    
    
    Special Installation Instructions:
    
         o  Scripting of Answers to Installation Questions
    
            During installation, this kit will ask and require user
            response to several questions.  If you wish to automate the
            installation of this kit and avoid having to provide responses
            to these questions, you must create a DCL command procedure
            that includes the following definitions and commands:
    
               -  $ DEFINE/SYS NO_ASK$BACKUP TRUE
    
               -  Add the following qualifiers to the PRODUCT INSTALL
                  command and add that command to the DCL procedure.
    
                    /PROD=DEC/BASE=AXPVMS/VER=V3.0
    
    
               -  De-assign the logicals assigned
    
            For example, a sample command file to install the
            VMS73_DCL-V0300 kit would be:
    
              $
              $ DEFINE/SYS NO_ASK$BACKUP TRUE
              $!
              $ PROD INSTALL VMS73_DCL/PROD=DEC/BASE=AXPVMS/VER=V3.0
              $!
              $ DEASSIGN/SYS NO_ASK$BACKUP
              $ DEASSIGN/SYS NO_ASK$REBOOT
              $!
              $ exit
      
      ==========================================================================
      |                     Table of Kit Image Information                     |
      +----------------------------+----------+-----------------+--------------+
      |                            | Overall  | Image File      | Image Link   |
      | Image Name                 | Checksum | Identification  | Date/Time    |
      +----------------------------+----------+-----------------+--------------+
      | DCL.EXE                    | 4EDC660D | X-18            | 11-FEB-2003  |
      |                                       |                 | 14:13:09.53  |
      +----------------------------+----------+-----------------+--------------+
    
    