Australia - Updated: 24-SEP-2003
hp.com home products and services support and drivers solutions how to buy
» contact hp
hp.com home hp OpenVMS ECOs

IMPORTANT NOTICE

The online distribution of OpenVMS and related product patches is being migrated to the HP ITRC (Information Technology Resource Center) patch distribution site. The new ITRC patch server will allow OpenVMS customers to take advantage of many enhanced features for patch searching and distribution.

Beginning August 1, 2003, OpenVMS and related Layered Product, publicly available patches will be available from the HP ITRC web site at

http://itrc.hp.com/service/patch/mainPage.do

The same patches will still be available from the existing patch server in Colorado Springs (http://www.support.compaq.com/patches/) through the end of October 2003, to give customers sufficient time to update their bookmarks and make the transition to the HP ITRC web site.

ECO kits will also be available by raw FTP from (ftp://ftp.itrc.hp.com/).

PLEASE UPDATE YOUR BOOKMARKS AND REGISTER ON THE NEW SITE NOW

Note: if you're having trouble connecting to the ITRC site, please delete any cookies for "itrc.hp.com" from your browser and try again. Report any difficulties with or suggestions to MrVMS

» Sydney CSC home page

Navigation
» ECOinfo main index
» Search ECOs
» Search FTP site
» Browse FTP site

ECO Indexes
» Chronological Index
» Indexed by Version
» Indexed by Rating
» Alpha Indexed by Name
» VAX Indexed by Name
» On Hold List

Associated Links
» OpenVMS Home Page
» OpenVMS News
» DIA/WIS Web Service

Feedback
» mail to CSC
.
Sydney Customer Support Centre OpenVMS ECO information
    Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)

VMS73_F11X-V0100 Alpha V7.3 F11BXQP ECO Summary

To obtain this kit please call the Customer Support Centre or use the FTP site

Search for this ECO kit and dependencies
Search the Compaq FTP web site this kit (exact match)
Search the Compaq FTP web site this or related ECOs

    
      
      
    Copyright (c) Compaq Computer Corporation 2002.  All rights reserved.
    
    Modification Date:  29-APR-2002
    Modification Date:  Not Applicable
    Modification Type:  NEW KIT
    
    OP/SYS:     OpenVMS Alpha
    
    COMPONENT:  F11BXQP
    
    SOURCE:     Compaq Computer Corporation
    
    ECO INFORMATION:
    
         ECO Kit Name:  VMS73_F11X-V0100
                        DEC-AXPVMS-VMS73_F11X-V0100--4.PCSI
         ECO Kits Superseded by This ECO Kit:  None
         ECO Kit Approximate Size:  928 Blocks
         Kit Applies To:  OpenVMS Alpha V7.3
         System/Cluster Reboot Necessary:  Yes
         Rolling Re-boot Supported:  Yes
         Installation Rating:  INSTALL_1
                               1 - To be installed by all customers.
    
         Kit Dependencies:
    
           The following remedial kit(s), or later, must be installed BEFORE
           installation of this, or any required kit:
    
              VMS73_UPDATE-V0100
    
           In order to receive all the corrections listed in this
           kit, the following remedial kits, or later, should also be installed:
    
              VMS73_RMS-V0300
    
    
    ECO KIT SUMMARY:
    
    An ECO kit exists for the F11BXQP on OpenVMS Alpha V7.3.  This kit
    addresses the following problems:
    
    PROBLEMS ADDRESSED IN VMS73_F11X-V0100 KIT:
    
      o  A synchronization issue between RMS's read of directory  files
         for  wildcard  operations and concurrent XQP activity has been
         identified and  corrected.   Prior  to  this  change,  it  was
         possible  that  RMS  could  obtain  an  inconsistent view of a
         directory file when reading it into its internal cache.   This
         could result in spurious RMS-E-FNF (file not found) errors.  A
         synchronization mechanism has been implemented between the XQP
         and  RMS  in  order  to  ensure  that  a  consistent view of a
         directory is achieved.
    
         In order to get this complete fix, you also  need  to  install
         the VMS73_RMS-V0300 ECO kit.
    
              Images Affected:  [SYS$LDR]F11BXQP.EXE
    
    
    
    
      o  The system can crash with a "MAPCNTZER, Attempted to  generate
         zero length map pointer" bugcheck.
    
         Crashdump Summary:
         ------------------
         Bugcheck Type:     MAPCNTZER, Attempted to generate zero
                            length map pointer
         Current Process:   _TNA69:
         Current Image:     DSA0:[SYS0.SYSCOMMON.][SYSEXE]SYSGEN.EXE
         Failing PC:        FFFFFFFF.A89F6B98    MAKE_POINTER_C+00044
         Failing PS:        30000000.00000000
         Module:            F11BXQP
                            (Link Date/Time: 24-AUG-2000 07:20:45.47)
         Offset:            00026B98
    
         R3 = 00000000.00000000 <<< value of COUNT - ARG1: block count
    
         SDA> CLUE STACK
    
         Stack Frame:
         PV       00000000.7B009230  FFFFFFFF.A8A28390 MAKE_POINTER
         Entry Point                 FFFFFFFF.A89F6B54 MAKE_POINTER_C
                  00000000.7B009238  00000000.0090AE6C
         return PC 00000000.7B009240 FFFFFFFF.A89F1DBC EXTEND_C+00978
                                                       ^^^^^^^ caller
         saved R2      00000000.7B009248  FFFFFFFF.A8A275D0  EXTEND
         saved R3      00000000.7B009250  00000000.00000000
         saved R8      00000000.7B009258  00000000.00000000
         saved FP      00000000.7B009260  00000000.7B009270
    
    
              Images Affected:  [SYS$LDR]F11BXQP.EXE
    
    
      o  On  Multi-Path  devices,  a   MONITOR   DISK/ITEM=QUEUE_LENGTh
         command  will  show  a  high  queue length.  It will stay high
         until reboot.  The queue length on a switched path device,  as
         seen from SDA, will show as negative.
    
              Images Affected:  [SYS$LDR]F11BXQP.EXE
    
    
    
    RELATED ARTICLES:
    
    Detailed articles describing the problems listed above may exist in
    the OPENVMS database.  To view these articles, open the appropriate
    product database and perform a query using either of the following
    search strings: 'VMS73_F11X-V0100,' 'ALPF11X,' VMS73_F11X,' or
    'DEC-AXPVMS-VMS73_F11X-V0100--4.PCSI.'
      
    
    ECO KIT ORDERING INSTRUCTIONS:
    
    If after an evaluation you wish to obtain this kit, request it
    electronically using the appropriate Advanced Electronic Services
    (AES) Service Tool.  If you are not familiar with how to request
    kits electronically, open the DIA, WIS or DSNLINK database and
    review the article entitled:
    
         [AES] How To Electronically Request ECO Kits Using Service Tools
    
    
    INSTALLATION NOTES:
    
    This kit requires a system reboot.  Compaq strongly recommends that
    a  reboot  is performed immediately after kit installation to avoid
    system instability
    
    If you have other nodes in your OpenVMS cluster, they must also  be
    rebooted  in  order  to make use of the new image(s).  If it is not
    possible or convenient to reboot the entire cluster at this time, a
    rolling re-boot may be performed.
    
    INSTALLATION INSTRUCTIONS:
    
    Install this kit with the POLYCENTER Software installation  utility
    by logging into the SYSTEM account, and typing the following at the
    DCL prompt:
    
    PRODUCT INSTALL VMS73_F11X /SOURCE=[location of Kit]
    
    The kit location may be a tape drive, CD, or a disk directory that
    contains the kit.
    
    Additional help on installing PCSI kits can be found by typing
    HELP PRODUCT INSTALL at the system prompt
    
    SPECIAL INSTALLATION INSTRUCTIONS:
    
      o  Scripting of Answers to Installation Questions
    
         During installation,  this  kit  will  ask  and  require  user
         response  to  several  questions.  If you wish to automate the
         installation of this kit and avoid having to provide responses
         to  these  questions,  you must create a DCL command procedure
         that includes the following definitions and commands:
    
               -  $ DEFINE/SYS NO_ASK$BACKUP TRUE
    
               -  $ DEFINE/SYS NO_ASK$REBOOT TRUE
    
               -  Add  the  following  qualifiers  to  the  PRODUCT  INSTALL
                  command and add that command to the DCL procedure.
    
                    /PROD=DEC/BASE=AXPVMS/VER=V1.0
    
               -  De-assign the logicals assigned
    
         For  example,  a  sample   command   file   to   install   the
         VMS73_F11X-V0100 kit would be:
    
              $
              $ DEFINE/SYS NO_ASK$BACKUP TRUE
              $ DEFINE/SYS NO_ASK$REBOOT TRUE
              $!
              $ PROD INSTALL VMS73_F11X/PROD=DEC/BASE=AXPVMS/VER=V1.0
              $!
              $ DEASSIGN/SYS NO_ASK$BACKUP
              $ DEASSIGN/SYS NO_ASK$REBOOT
              $!
              $ exit
    
    
      
      ==========================================================================
      |                     Table of Kit Image Information                     |
      +----------------------------+----------+-----------------+--------------+
      |                            | Overall  | Image File      | Image Link   |
      | Image Name                 | Checksum | Identification  | Date/Time    |
      +----------------------------+----------+-----------------+--------------+
      | F11BXQP.EXE                | DD744EC7 | XQP V7.3R-0001  |  4-MAR-2002  |
      |                                       |                 | 15:21:22.80  |
      +----------------------------+----------+-----------------+--------------+
    
    
    All trademarks are the property of their respective owners.
    