Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
ALPCLIU02_071 (Alpha V7.1 SHWCLSTR) ECO Summary
Copyright (c) Compaq Computer Corporation 1997. All rights reserved.
PRODUCT: OpenVMS Alpha
COMPONENT: CLIUTL - SHWCLSTR.EXE
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: ALPCLIU02_071
ECO Kits Superseded by This ECO Kit: ALPCLIU01_071
ECO Kit Approximate Size: 430 Blocks
Kit Applies To: OpenVMS Alpha V7.1 through V7.1-1H2
System/Cluster Reboot Necessary: Yes
Installation Rating: 3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
NOTE: In order to receive the full fixes listed in this kit,
the following remedial kits also need to be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for the DCL command 'SHOW CLUSTER' (SHWCLSTR) on
OpenVMS Alpha V7.1 through V7.1-1H2. This kit addresses the
following problems:
Problems Addressed in the ALPCLIU02_071 Kit:
o The ALPCLIU01_071 remedial kit did not fully correct the problems
listed. This kit does that.
Problems Addressed in the ALPCLIU01_071 Kit:
o System crashes with a PGFIPLHI, Pagefault with Interrupt Priority
Level (IPL) too high, after entering a SHOW CLUSTER/CONT command
and adding PORT class information.
Crash FOOTPRINT: From SDA> CLUE CRASH
Crash Time: 28-APR-1997 09:41:36.33
Bugcheck Type: PGFIPLHI, Pagefault with IPL too high
Node: XXXX (Clustered)
CPU Type: Alpha
VMS Version: V7.1
Current Process: XXXX
Current Image: $1$DUA50:[SYS4.SYSCOMMON.][SYSEXE]SHWCLSTR.EXE
Failing PC: 00000000 00061080
Failing PS: 2C000000 00000803
Module: SHWCLSTR
Offset: 00061080
o Modified date and time format for the SHOW CLUSTER utility. Signed
integer fields can now be displayed.
o For date/time display elements, the SHOW CLUSTER command shows only
the last two digits of the year. This can be seen by executing
any of the following 'Add' commands in SHOW CLUSTER/CONTINUOUS:
SHOW CLUSTER/CONTINUOUS
Add> ADD FORMED
Add> ADD LAST_TRANSITION
Add> ADD TRANSITION
If the system time is set to sometime in the year 2000, the year
is displayed as "00".
This change allows year to be displayed as a full four digit number.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in
OPENVMS database. To view these articles, open the appropriate product
database and perform a query using either of the following search
strings: 'ALPCLIU02_071' or 'ALPCLIU'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, open the DIA, WIS or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
In order for the corrections in this kit to take effect, the system must
be rebooted. If the system is a member of a VMScluster, the entire
cluster should be rebooted.
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| SHWCLSTR.EXE | BAB7126F | X-17A2 | 22-AUG-1997 |
| | | 16:34:03.64 |
+----------------------------+----------+-----------------+--------------+
|