ALPLOGI02_061 Alpha V6.1 LOGINOUT ECO Summary
Copyright (c) Digital Equipment Corporation 1997. All rights reserved.
PRODUCT: OpenVMS Alpha
COMPONENT: LOGINOUT
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: ALPLOGI02_061
ECO Kits Superseded by This ECO Kit: ALPLOAD02_070 (For Alpha
V6.1 *ONLY*)
ALPLOAD01_070
AXPLOGI01_061
ECO Kit Approximate Size: 1098 Blocks
Kit Applies To: OpenVMS Alpha V6.1, V6.1-1H1, V6.1-1H2
System/Cluster Reboot Necessary: No
Installation Rating: 3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
NOTE: In order to receive the full fixes listed in this kit,
the following remedial kits also need to be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for LOGINOUT on OpenVMS Alpha V6.1, V6.1-1H1, V6.1-1H2.
This kit addresses the following problems:
Problems addressed in ALPLOGI02_061 Kit
o These OpenVMS Alpha V6.1 problem corrections were included in
the multi-version ALPLOAD02_070 remedial kit. They are now
being issued as a V6.1 only remedial kit.
There are no new problem corrections in this remedial kit.
Problems addressed in ALPLOAD01_070 Kit for OpenVMS V6.1, V6.1-1H1, V6.1-1H2
o Some logins are not correctly audited.
o Users without WORLD privilege generate many "No WORLD priv"
audits when logging in.
Problems addressed in AXPLOGI01_061 Kit
o There will be no audit records written or displayed after a
user is prompted for, and successfully enters, a new password
at login time.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in
the OPENVMS database. To view these articles, open the appropriate
product database and perform a query using either of the following
search strings: 'ALPLOGI02_061' or 'ALPLOGI'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, open the DIA, WIS or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
The system does not need to be rebooted after this kit is installed.
However, if you have other nodes in your OpenVMS VMScluster, they should
be rebooted or you should install this kit on each system in order to
make use of the new image(s).
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| LOGINOUT.EXE | 17F00234 | X-13U2 | 30-AUG-1996 |
| | | 15:30:34.11 |
+----------------------------+----------+-----------------+--------------+
|