Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
STRIPEVAXE02021 VAX V5.4 - V6.1 Striping ECO Summary
Copyright (c) Digital Equipment Corporation 1998. All rights reserved.
PRODUCT: POLYCENTER Striping for OpenVMS VAX, Version 2.1
OP/SYS: OpenVMS VAX
COMPONENT: Striping Driver (STDRIVER)
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: STRIPEVAXE02021
ECO Kits Superseded by This ECO Kit: STRIPEVAXE01021
ECO Kit Approximate Size: 1897 Blocks
Saveset A: 1890 Blocks
Kit Applies To: POLYCENTER Striping for OpenVMS VAX V2.1 on
OpenVMS VAX V5.4, V5.4-1, V5.4-2, V5.4-3,
V5.5, V5.5-1, V5.5-2, V6.0, V6.1
System/Cluster Reboot Necessary: Yes
NOTE: The installation kit for this ECO does not contain any
executable images. The appropriate image will be
generated by the object modules at installation time
depending upon the version of OpenVMS VAX to which
the kit is applied.
ECO KIT SUMMARY:
An ECO kit exists for the Striping Driver on OpenVMS VAX V5.4
through V6.1. This kit addresses the following problems:
PROBLEMS ADDRESSED IN STRIPEVAXE02021:
NOTE: This kit contains a remedial to correct behavior caused by the
use of OpenVMS patch kit VAXSHAD09, "shadowing writes past the
legal length of an IRP for OpenVMS V6.1 and earlier". In OpenVMS
V6.2, OpenVMS expanded the size of the IRP data structure. The
VAXSHAD09 patch kit utilizes these values for 6.2 and earlier
versions of OpenVMS.
o Increase the size of the structure that contain the member IRPs.
PROBLEMS ADDRESSED IN STRIPEVAXE01021:
o If a BIND fails because a stripeset is already bound,
some of the existing stripeset data structures are
deallocated.
o When a stripeset is initialized using the /FILES_11
qualifier, a signed comparison is made against the 8.5
GB limit. This may cause a stripeset larger that 8.5 GB
to be created.
o The BIND_UNBIND_LCK descriptor is not locked down. This
might cause a PGFIPLHI bugcheck to could occur when binding
a stripeset.
o Incorrectly clearing the UCB$W_REFC field causes a negative
reference count and dangling locks with cleared value blocks
for a stripeset device.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in
the STORAGE and OPENVMS databases. To view these articles, open
the appropriate product database and perform a query using either of
the following search strings: 'STRIPEVAXE02021' or 'STRIPEVAX'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, please open the DIA or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
The system must be rebooted after this kit is installed to make use
of the new images. If you have other nodes in your OpenVMS VAXcluster, they
must be rebooted or you must install this kit on each system in order
to make use of the new images.
|