Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
ALPRTPA01_061 (Alpha V6.1 CTDRIVER) ECO Summary
Copyright (c) Digital Equipment Corporation 1997. All rights reserved.
PRODUCT: OpenVMS Alpha, Versions 6.1, 6.1-1H1, 6.1-1H2
COMPONENT: SYS$CTDRIVER.EXE
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: ALPRTPA01_061
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 300 Blocks
Kit Applies To: OpenVMS Alpha V6.1, V6.1-1H1, V6.1-1H2
System/Cluster Reboot Necessary: Yes
Installation Rating: 1 - To be installed on all systems running
the listed version(s) of OpenVMS.
NOTE: In order to receive the full fixes listed in this kit,
the following remedial kits also need to be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for CTDRIVER.EXE on OpenVMS Alpha V6.1 through
V6.1-1H2. This kit addresses the following problems:
Problems Addressed in the ALPRTPA01_061 Kit:
o If there is an I/O error, then there is an attempt to remove the
current Interrupt Request Packet (IRP). If there is a buffer
associated with this IRP, then the buffer is deallocated. But,
before the IRP itself is removed, the caller is returned and the IRP
is left hanging. The user might see this as a loss of nonpaged
pool. Over a period of time this could exhaust the pool in the
system.
o The user will see this in several different ways depending on how
the registers R9 and/or R10 are being used. The result could be a
process hang or system crash.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in the
OPENVMS database. To view these articles, open the appropriate product
database and perform a query using either of the following search
strings: 'ALPRTPA01_061' or 'ALPRTPA'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, open the DIA, WIS or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
In order for the corrections in this kit to take effect, the system must
be rebooted. If the system is a member of a VMScluster, the entire
cluster should be rebooted.
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| SYS$CTDRIVER.EXE | DA5F8EDC | X-3 | 4-MAR-1997 |
| | | 11:30:11.02 |
+----------------------------+----------+-----------------+--------------+
|