Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
VAXDISM01_U2055 VAX V5.5-2, V5.5-2H4 DISMOUNT ECO Summary
Copyright (c) Digital Equipment Corporation 1994. All rights reserved.
OP/SYS: OpenVMS VAX
COMPONENTS: DISMOUNT.EXE
DISMNTSHR.EXE
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: VAXDISM01_U2055
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 100 Blocks
Kit Applies To: OpenVMS VAX V5.5-2, V5.5-2H4
System Reboot Necessary: No
ECO KIT SUMMARY:
An ECO kit exists for DISMOUNT and DISMNTSHR on OpenVMS VAX V5.5-2
through V5.5-2H4. This kit addresses the following problems:
Problems addressed in the VAXDISM01_U2055 kit:
o A tape drive remains allocated even after the process that had
allocated it has terminated. The tape drive is then unavailable
for any other use. An example is shown below.
EXAMPLE:
$ sho device/full mua0
Magtape $90$MUA0: (YELLO), device type TA90, is online,
allocated, controller supports tape data caching (write-back
cache enabled), mounted foreign , record - oriented device,
file-oriented device , available to cluster, error logging is
enabled.
Error count 15 Operations completed 122191
Owner process "" Owner UIC [FIELD,OPERATOR]
Owner process ID 20802A14 Dev Prot S:RWED,O:RWED,G:,W:
Reference count 2 Default buffer size 65024
Volume label "*B*002" Relative volume no. 0
Record size 0 Transaction count 1
Mount status Process Mount count 1
ACP process name ""
Density 39782 Format Normal-11
Volume status: odd parity.
$ sh process/id=20802A14
%SYSTEM-W-NONEXPR, nonexistent process
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in
the OPENVMS database. To view these articles, open the appropriate
product database and perform a query using either of the following the
search strings: 'VAXDISM01_U2055' or 'VAXDISM'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, open the DIA, WIS or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
The system does not need to be rebooted after this kit is installed.
However, if you have other nodes in your VAXcluster, they should be
rebooted or you should install this kit on each system in order to make
use of the new image(s).
==========================================================================
| Table of Kit Image Information |
+----------------------------+----------+-----------------+--------------+
| | Overall | Image File | Image Link |
| Image Name | Checksum | Identification | Date/Time |
+----------------------------+----------+-----------------+--------------+
| DISMNTSHR.EXE |%X51B1B5BF| X-2 | 12-APR-1994 |
| | | 22:31:24.50 |
+----------------------------+----------+-----------------+--------------+
| DISMOUNT.EXE |%X2C7BC00E| X-3 | 12-APR-1994 |
| | | 22:55:50.79 |
+----------------------------+----------+-----------------+--------------+
|