Updated: 24-SEP-2003 (Use your browsers' Reload button to ensure you're viewing the most recent version)
COBOLVAXE01053 VAX COBOL V5.3 for OpenVMS VAX ECO Summary
Copyright (c) Digital Equipment Corporation 1995, 1996. All rights reserved.
PRODUCT: VAX COBOL
COMPONENTS: VAX COBOL Run-Time Library (RTL) - COBRTL.EXE
VAX COBOL Compiler - COBOL.EXE
OP/SYS: OpenVMS VAX
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: COBOLVAXE01053
ECO Kits Superseded by This ECO Kit: COBRTLVAXE01053
ECO Kit Approximate Size: COBOLVAXE01053.A - 7812 Blocks
NOTE: The saveset COBOLVAXE01053.A contains the installation
files COBOL053.A, COBOL053.B, and COBOL053.C as well
as the ECO Release Notes, COBOLVAXE01053.RELEASE_NOTES.
You must first restore the saveset COBOLVAXE01053.A
and then specify the installation file COBOL053 when
using the VMSINSTAL command to apply this ECO. Refer
to the INSTALLATION NOTES Section for more detail.
Kit Applies To: VAX COBOL V5.3
OpenVMS VAX V5.5-2 or later
OpenVMS/Japanese VAX V5.5-2 or later
System Reboot Necessary: No
ECO KIT SUMMARY:
An ECO kit exists for VAX COBOL V5.3 on OpenVMS VAX V5.5-2 or higher.
Problems addressed in the COBOLVAXE01053 Kit:
o A runtime problem with RMS Special Registers has been corrected
which would cause an ACCVIO on OPEN or result in incorrect values
for RMS Special Registers.
o An edit has been applied in order to support APPLY DEFERRED-WRITE
for ORGANIZATION SEQUENTIAL at runtime.
Problems addressed in the COBRTLVAXE01053 Kit:
o This ECO kit contains corrections to the VAX Cobol Run-Time Library
which are equivalent to the corrections released with the VAX COBOL
Run-Time Library supplied with OpenVMS VAX V6.2.
o In addition, this ECO also corrects the following problem.
When reading from the process permanent file, SYS$INPUT, in batch,
the EOF is ignored if the ACCEPT statement has both a PROTECTED and a
DEFAULT clause.
RELATED ARTICLES:
Detailed articles describing the problems listed above may exist in the
COBOL database. To view these articles, open the appropriate product
database and perform a query using the search string 'COBOLVAXE01053'.
ECO KIT ORDERING INSTRUCTIONS:
If after an evaluation you wish to obtain this kit, request it
electronically using the appropriate Advanced Electronic Services
(AES) Service Tool. If you are not familiar with how to request
kits electronically, open the DIA, WIS or DSNLINK database and
review the article entitled:
[AES] How To Electronically Request ECO Kits Using Service Tools
INSTALLATION NOTES:
o Set default to a directory of your choice.
o Use the VMS BACKUP Utility to unload the installation files from the
COBRTLVAXE01053.A saveset to your directory. For example,
BACKUP COBRTLVAXE01053.A/SAVE *.*
This command will place four files into your directory.
COBOL053.A;42
COBOL053.B;42
COBOL053.C;42
COBOLVAXE01053.RELEASE_NOTES;11
o Copy the release notes, COBOLVAXE01053.RELEASE_NOTES, to
SYS$HELP. For example,
COPY COBOLVAXE01053.RELEASE_NOTES SYS$HELP
o Install this kit using the VMSINSTAL utility by logging into the
SYSTEM account, and then follow the installation instructions given
in the VAX COBOL Installation Guide which was supplied with VAX COBOL
V5.3. For example,
@SYS$UPDATE:VMSINSTAL COBOL053 [location of the saveset]
The system does not need to be rebooted after this kit is installed.
However, if you have other nodes in your VAXcluster, follow the
instructions in the VAX COBOL installation guide for installing
VAX COBOL on a cluster.
|